Ignition of gas leads to underground fire
The mine safety operations branch of NSW government has issued a safety alert following a fire in the longwall goaf of an underground coal mine.
An ignition of gas led to a fire, which resulted in the evacuation of the underground workforce. An afternoon-shift crew was conducting maintenance on the longwall that had been on maintenance since the start of day shift. The bulk of the crew was conducting maintenance at the main gate with one fitter working further in, about two-thirds of the way to the tailgate. Midway through the shift there was an air blast of sufficient force to knock the fitter over and be strongly felt by the crew at the main gate. This was followed by a significant reversal of air. The mine deputy proceeded to the tailgate where he found an open fire coming from the tailgate goaf. He evacuated the unit and alerted the control room to evacuate the mine.
At the time of the incident there was a severe lightning storm. The seam being worked contained significant amounts of methane and the mine had a sophisticated drainage system, with both pre- and post-drainage in place. The longwall panel was the first to be worked in this seam. The seam being worked was overlain by a previously worked out seam. An investigation into the cause of the ignition and the emergency response is continuing. The investigation process has taken some time because of the complexity of issues under investigation.
Areas investigated include:
- Possible causes of the ignition
- lightning strike
- spontaneous combustion
- electrical ignition
- mechanical heat sources
- contraband
- frictional ignition
- Mine safety systems and procedures
- environmental monitoring
- ventilation systems
- trigger action response plans (TARPs)
- Emergency response
- training and competence of surface emergency personnel
- use of emergency escape equipment
- training of the workforce in the use of emergency equipment
The department recommends that mine operators;
- review emergency management procedures and training, including the appropriate use of oxygen-generating emergency escape safety equipment
- review the competence and training of surface emergency personnel
- review the adequacy of gas monitoring including alarm setting, calibration and trigger action response plans
- review the adequacy of mine lightning protection and the removal, isolation or earthing of possible conduction paths
- regularly review spontaneous combustion management plans to ensure its relevance in the current working environment
- review the adequacy of engineering controls to prevent an ignition source
- review procedures to eliminate contraband entering underground workings
- review the need to inert goaf fringes to prevent a possible flammable mixture contacting ignition sources such as frictional sparking
- remind managers, supervisors, other employees and contractors of their obligations under the Occupational Health and Safety Act 2000 and the Coal Mine Health and Safety Act 2002.
New workplace exposure limits for airborne contaminants
The workplace exposure limits for airborne contaminants (WEL list) will be adopted throughout...
New exposure standard to improve welder safety outcomes
Work Health and Safety Ministers have agreed to reduce the workplace exposure standard for...
New campaign shines light on safe gas appliance use
Resources Safety and Health Queensland (RSHQ) has launched a campaign to ensure small food...